Assessment Year 2024
Principal Product Custom stone kitchen & bath products
NAICS 423320: Brick, Stone, and Related Construction Material Merchant Wholesalers
SIC 5032: Brick, Stone, and Related Construction Materials
Sales Range $1
M
to 5
M
# of Employees 87
Plant Area 100,000
ft2
Annual Production 7,000
units
Production Hrs. Annual 3,120
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $58,698 757,800
kWh
Electricity Demand $9,282 2,376
kW-mo/yr
Electricity Fees $13,607 -
Natural Gas $8,225 680
MMBtu
Fuel Oil #2 $439,715 16,119
MMBtu
Waste Disposal Costs
Water Usage $6,889 422
Tgal
TOTAL YEARLY COSTS $536,416
RECOMMENDED SAVINGS* $31,171 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $474 $100 $396
5,148
kWh
$78
-
kW-mo/yr
-
02 2.7261: Install timers and/or thermostats $2,648 $960 $2,624
34,075
kWh
- $24
-
MMBtu
03 2.7135: Install occupancy sensors $307 $140 $307
3,991
kWh
- -
04 2.2443: Re-use or recycle hot or cold process exhaust air $5,106 $2,500 - - $5,106
-
MMBtu
05 2.7232: Replace existing hvac unit with high efficiency model $14,800 $19,440 - - $14,800
-
MMBtu
06 2.7232: Replace existing hvac unit with high efficiency model $6,361 $21,000 $6,189
80,371
kWh
$172
-
kW-mo/yr
-
07 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle $1,253 $9,000 $(-358.0)
(-4,653)
kWh
$(-35.0)
-
kW-mo/yr
$1,646
-
MMBtu
08 2.7142: Utilize higher efficiency lamps and/or ballasts $222 $1,600 $179
2,330
kWh
$43
-
kW-mo/yr
-
TOTAL RECOMMENDED $31,171 $54,740 $9,337
121,262
kWh
$258
-
kW-mo/yr
$21,576
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs