Assessment Year | 2024 |
---|---|
Principal Product | Nutritional Products |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 1,000 |
Plant Area |
2,000,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $4,868,898 | 54,098,868 |
kWh
|
$0.090 |
Electricity Demand | $426,088 | 79,941 |
kW-mo/yr
|
$5.33 |
Electricity Fees | $71,476 | - |
|
- |
Natural Gas | $3,848,626 | 590,280 |
MMBtu
|
$6.52 |
TOTAL YEARLY COSTS | $9,215,088 | |||
RECOMMENDED SAVINGS* | $607,732 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $40,483 | $4,800 |
$37,373
415,257
kWh
|
- |
$3,110
-
MMBtu
|
|
02 | 2.7261: Install timers and/or thermostats | $15,790 | $7,920 |
$12,458
138,419
kWh
|
- |
$3,332
-
MMBtu
|
|
03 | 2.2113: Repair or replace steam traps | $49,962 | $35,200 | - | - |
$49,962
-
MMBtu
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $28,403 | $21,160 |
$26,266
291,850
kWh
|
$2,137
-
kW-mo/yr
|
- | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $17,514 | $16,000 |
$16,197
179,962
kWh
|
$1,317
-
kW-mo/yr
|
- | |
06 | 2.7261: Install timers and/or thermostats | $4,850 | $4,800 |
$3,064
34,045
kWh
|
- |
$1,786
-
MMBtu
|
|
07 | 2.4224: Upgrade controls on compressors | $306,071 | $500,000 |
$283,046
3,144,960
kWh
|
$23,025
-
kW-mo/yr
|
- | |
08 | 2.2128: Use steam condensate for hot water supply (non-potable) | $101,613 | $202,500 |
$(-2,525.0)
(-28,050)
kWh
|
- |
$104,138
-
MMBtu
|
|
09 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $43,046 | $90,000 |
$41,058
456,200
kWh
|
$1,988
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $607,732 | $882,380 |
$416,937
4,632,643
kWh
|
$28,467
-
kW-mo/yr
|
$162,328
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs