Assessment Year | 2022 |
---|---|
Principal Product | Coated Glass Products |
NAICS | 333314: Optical Instrument and Lens Manufacturing |
SIC | 3827: Optical Instruments and Lenses |
Sales Range | $1 M to 5M |
# of Employees | 35 |
Plant Area |
46,000
ft2
|
Annual Production | 120,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $244,865 | 2,689,400 |
kWh
|
$0.091 |
Electricity Demand | $38,003 | 5,511 |
kW-mo/yr
|
$6.90 |
Electricity Fees | $4,450 | - |
|
- |
Natural Gas | $4,540 | 357 |
MMBtu
|
$12.72 |
TOTAL YEARLY COSTS | $291,858 | |||
RECOMMENDED SAVINGS* | $60,970 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $58,607 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|
01 | 4.821: Pay bills on time to avoid late fees | $1,805 | - | - | - | $1,805 | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $103 | $40 |
$76
837
kWh
|
$27
-
kW-mo/yr
|
- | - | |
03 | 2.7261: Install timers and/or thermostats | $2,621 | $1,330 |
$2,621
28,805
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,500 | $3,435 |
$4,074
44,772
kWh
|
$1,426
-
kW-mo/yr
|
- | - | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $32,527 | $500,000 |
$30,029
329,987
kWh
|
$2,498
-
kW-mo/yr
|
- | - | |
06 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $2,260 | $8,500 |
$1,760
19,336
kWh
|
$500
-
kW-mo/yr
|
- | - | |
07 | 2.2622: Replace existing chiller with high efficiency model | $16,154 | $160,000 | - | - | - | $16,154 | |
TOTAL RECOMMENDED | $60,970 | $673,305 |
$38,560
423,737
kWh
|
$4,451
-
kW-mo/yr
|
$1,805 | $16,154 | ||
TOTAL IMPLEMENTED | $58,607 | $664,765 |
$36,724
403,564
kWh
|
$3,924
-
kW-mo/yr
|
$1,805 | $16,154 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs