Assessment Year | 2022 |
---|---|
Principal Product | Recycled paper |
NAICS | 322121: Paper (except Newsprint) Mills |
SIC | 2621: Paper Mills |
Sales Range | $100 M to 500M |
# of Employees | 78 |
Plant Area |
240,000
ft2
|
Annual Production | 322,120
ton
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $3,661,563 | 80,145,784 |
kWh
|
$0.046 | |
Electricity Demand | $124,000 | 129,169 |
kW-mo/yr
|
$0.96 | |
Electricity Fees | $185,700 | - |
|
- | |
Natural Gas | $5,011,370 | 932,753 |
MMBtu
|
$5.37 | |
Waste Disposal Costs | |||||
Water Usage | $694,380 | 103,212 |
Tgal
|
$6.73 | |
Water Disposal | $2,283,069 | 188,457 |
Tgal
|
$12.11 | |
TOTAL YEARLY COSTS | $11,960,082 | ||||
RECOMMENDED SAVINGS* | $2,541,734 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $609,889 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Water Consumption Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,559 | $100 |
$2,487
54,053
kWh
|
$72
-
kW-mo/yr
|
- | - | - | - | |
02 | 2.2442: Preheat combustion air with waste heat | $131,350 | $40,000 | - | - |
$131,350
-
MMBtu
|
- | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,133 | $7,750 |
$16,655
362,058
kWh
|
$478
-
kW-mo/yr
|
- | - | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,786 | $5,740 |
$9,533
207,242
kWh
|
$253
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $29,876 | $25,340 |
$29,044
631,388
kWh
|
$832
-
kW-mo/yr
|
- | - | - | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $2,341 | $2,100 |
$2,276
49,453
kWh
|
$65
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.2121: Increase amount of condensate returned | $247,341 | $500,000 | - | - |
$35,957
-
MMBtu
|
- |
$135,648
-
Tgal
|
$75,736
-
Tgal
|
|
08 | 3.1181: Eliminate a by-product | $1,467,534 | $3,000,000 |
$(-162,042.0)
(-3,424,512)
kWh
|
- |
$219,919
-
MMBtu
|
$505,064
-
Tgal
|
$904,593
-
Tgal
|
- | |
09 | 2.2121: Increase amount of condensate returned | $166,416 | $500,000 | - | - |
$29,191
-
MMBtu
|
$49,166
-
Tgal
|
$88,059
-
Tgal
|
- | |
10 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,992 | $24,000 | - | - |
$5,992
-
MMBtu
|
- | - | - | |
11 | 2.1224: Replace boiler | $461,406 | $4,000,000 | - | - |
$461,406
-
MMBtu
|
- | - | - | |
TOTAL RECOMMENDED | $2,541,734 | $8,105,030 |
$(-102,047.0)
(-2,120,318)
kWh
|
$1,700
-
kW-mo/yr
|
$883,815
-
MMBtu
|
$554,230
-
Tgal
|
$1,128,300
-
Tgal
|
$75,736
-
Tgal
|
||
TOTAL IMPLEMENTED | $609,889 | $4,047,750 |
$16,655
362,058
kWh
|
$478
-
kW-mo/yr
|
$592,756
-
MMBtu
|
- | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings | Water Consumption Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs