ITAC Assessment: LE0515
ITAC logo
ITAC Assessment: LE0515
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2021
Principal Product Tire Retreading
NAICS 326212: Tire Retreading
SIC 3011: Tires and Inner Tubes
Sales Range $10
M
to 50
M
# of Employees 85
Plant Area 95,000
ft2
Annual Production 85,000
units
Production Hrs. Annual 4,420
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $131,488 1,851,000
kWh
Electricity Demand $18,487 5,282
kW-mo/yr
Electricity Fees $4,033 -
Natural Gas $91,507 12,497
MMBtu
TOTAL YEARLY COSTS $245,515
RECOMMENDED SAVINGS* $167,219 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $157,618

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Increase in Production Savings
01 2.4231: Reduce the pressure of compressed air to the minimum required $2,213 - $1,929
27,164
kWh
$284
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,306 $1,500 $2,011
28,316
kWh
$295
-
kW-mo/yr
-
03 2.4221: Install compressor air intakes in coolest locations $1,441 $1,500 $1,255
17,685
kWh
$186
-
kW-mo/yr
-
04 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,979 $10,500 $7,918
111,527
kWh
$1,061
-
kW-mo/yr
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $1,658 $6,990 $1,462
20,597
kWh
$196
-
kW-mo/yr
-
06 2.4322: Use or replace with energy efficient substitutes $150,000 $700,000 - - $150,000
07 2.7232: Replace existing hvac unit with high efficiency model $622 $3,000 $584
8,223
kWh
$38
-
kW-mo/yr
-
TOTAL RECOMMENDED $167,219 $723,490 $15,159
213,512
kWh
$2,060
-
kW-mo/yr
$150,000
TOTAL IMPLEMENTED $157,618 $709,990 $6,657
93,762
kWh
$961
-
kW-mo/yr
$150,000
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Increase in Production Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs