Assessment Year | 2021 |
---|---|
Principal Product | Metal Fabrication |
NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
SIC | 3469: Metal Stampings, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
100,000
ft2
|
Annual Production | 100,000
pieces
|
Production Hrs. Annual | 2,860
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,977 | 1,457,977 |
kWh
|
$0.058 |
Electricity Demand | $13,871 | 4,355 |
kW-mo/yr
|
$3.19 |
Electricity Fees | $12,926 | - |
|
- |
Natural Gas | $38,001 | 4,536 |
MMBtu
|
$8.38 |
TOTAL YEARLY COSTS | $149,775 | |||
RECOMMENDED SAVINGS* | $10,866 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $9,259 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4239: Eliminate or reduce compressed air usage | $1,607 | $50 |
$1,470
25,344
kWh
|
$137
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,834 | $2,500 |
$1,706
29,405
kWh
|
$128
-
kW-mo/yr
|
|
03 | 2.4226: Use / purchase optimum sized compressor | $3,755 | $56,400 |
$3,433
59,182
kWh
|
$322
-
kW-mo/yr
|
|
04 | 2.7232: Replace existing hvac unit with high efficiency model | $2,037 | $8,000 |
$1,893
32,640
kWh
|
$144
-
kW-mo/yr
|
|
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,633 | $9,000 |
$1,327
22,880
kWh
|
$306
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $10,866 | $75,950 |
$9,829
169,451
kWh
|
$1,037
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $9,259 | $75,900 |
$8,359
144,107
kWh
|
$900
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs