ITAC Assessment: AM0744
ITAC logo
ITAC Assessment: AM0744
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Processed lumber
NAICS 321113: Sawmills
SIC 2421: Sawmills and Planing Mills, General
Sales Range $100
M
to 500
M
# of Employees 420
Plant Area 125,000
ft2
Annual Production 2,000
thousand feet
Production Hrs. Annual 7,748
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $286,116 4,628,400
kWh
Electricity Demand $80,500 13,362
kW-mo/yr
Electricity Fees $769 -
TOTAL YEARLY COSTS $367,385
RECOMMENDED SAVINGS* $52,222 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $43,383

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 4.611: Begin a practice of predictive / preventative maintenance $17,930 $4,570 $3,960
64,060
kWh
$1,500
-
kW-mo/yr
- $12,470
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $7,640 - $5,730
92,670
kWh
$1,910
-
kW-mo/yr
- -
03 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,150 $5,000 $5,770
93,340
kWh
$1,380
-
kW-mo/yr
- -
04 2.4231: Reduce the pressure of compressed air to the minimum required $5,840 $225 $4,700
76,060
kWh
$1,140
-
kW-mo/yr
- -
05 3.5212: Regrind, reuse, or sell scrap plastic parts $4,800 - - - $4,800
-
lb
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $4,928 $7,060 $4,260
68,900
kWh
$668
-
kW-mo/yr
- -
07 2.4239: Eliminate or reduce compressed air usage $1,880 $560 $1,880
30,460
kWh
- - -
08 2.7121: Utilize daylight whenever possible in lieu of artificial light $1,119 $1,800 $794
12,850
kWh
$325
-
kW-mo/yr
- -
09 2.7134: Use photocell controls $935 $180 $935
15,130
kWh
- - -
TOTAL RECOMMENDED $52,222 $19,395 $28,029
453,470
kWh
$6,923
-
kW-mo/yr
$4,800
-
lb
$12,470
TOTAL IMPLEMENTED $43,383 $16,810 $20,655
334,100
kWh
$5,458
-
kW-mo/yr
$4,800
-
lb
$12,470
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs