Assessment Year 2020
Principal Product Metal Fabricated Enclosures
NAICS 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing
SIC 3291: Abrasive Products
Sales Range $100
M
to 500
M
# of Employees 166
Plant Area 440,000
ft2
Annual Production 500,000
units
Production Hrs. Annual 6,240
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $230,298 5,499,608
kWh
Electricity Demand $74,679 13,993
kW-mo/yr
Electricity Fees $332,394 -
Natural Gas $151,105 21,314
MMBtu
TOTAL YEARLY COSTS $788,476
RECOMMENDED SAVINGS* $53,028 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.8114: Change rate schedules or other changes in utility service $30,000 - - - - $30,000
02 2.1311: Replace electrically-operated equipment with fossil fuel equipment $1,682 - $1,105
26,325
kWh
$577
-
kW-mo/yr
- -
03 2.6212: Turn off equipment during breaks, reduce operating time $3,482 $3,000 $1,955
46,550
kWh
$1,527
-
kW-mo/yr
- -
04 2.2437: Recover waste heat from equipment $3,545 $5,000 - - $3,545
-
MMBtu
-
05 2.7263: Lower compressor pressure through a/c system modification $1,393 $3,150 $1,121
26,681
kWh
$272
-
kW-mo/yr
- -
06 2.4231: Reduce the pressure of compressed air to the minimum required $1,207 $3,300 $977
23,275
kWh
$230
-
kW-mo/yr
- -
07 2.7232: Replace existing hvac unit with high efficiency model $6,578 $29,000 $4,874
116,052
kWh
$1,704
-
kW-mo/yr
- -
08 2.7142: Utilize higher efficiency lamps and/or ballasts $1,991 $9,200 $1,553
36,972
kWh
$438
-
kW-mo/yr
- -
09 2.7425: Clean or color roof to reduce solar load $3,150 $18,250 $1,650
39,285
kWh
$2,748
-
kW-mo/yr
$(-1,248.0)
-
MMBtu
-
TOTAL RECOMMENDED $53,028 $70,900 $13,235
315,140
kWh
$7,496
-
kW-mo/yr
$2,297
-
MMBtu
$30,000
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs