Assessment Year | 2019 |
---|---|
Principal Product | Dyeing and Bleaching Fabric |
NAICS | 313310: Textile and Fabric Finishing Mills |
SIC | 2269: Finishers of Textiles, Not elsewhere Classified |
Sales Range | $5 M to 10M |
# of Employees | 63 |
Plant Area |
80,000
ft2
|
Annual Production | 3,800,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $167,098 | 3,264,739 |
kWh
|
$0.051 |
Electricity Demand | $41,991 | 9,515 |
kW-mo/yr
|
$4.41 |
Electricity Fees | $23,674 | - |
|
- |
Natural Gas | $300,318 | 63,490 |
MMBtu
|
$4.73 |
LPG | $5,525 | 223 |
MMBtu
|
$24.78 |
TOTAL YEARLY COSTS | $538,606 | |||
RECOMMENDED SAVINGS* | $75,621 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $40,399 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7263: Lower compressor pressure through a/c system modification | $728 | $40 |
$622
12,204
kWh
|
$106
-
kW-mo/yr
|
- | - | |
02 | 2.2511: Insulate bare equipment | $5,562 | $1,833 | - | - |
$5,562
-
MMBtu
|
- | |
03 | 2.2113: Repair or replace steam traps | $11,267 | $5,000 | - | - |
$11,267
-
MMBtu
|
- | |
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,594 | $10,000 |
$6,703
131,436
kWh
|
$891
-
kW-mo/yr
|
- | - | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,823 | $10,000 |
$5,139
100,768
kWh
|
$684
-
kW-mo/yr
|
- | - | |
06 | 2.4221: Install compressor air intakes in coolest locations | $399 | $975 |
$342
6,696
kWh
|
$57
-
kW-mo/yr
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,408 | $16,552 |
$4,627
90,732
kWh
|
$781
-
kW-mo/yr
|
- | - | |
08 | 2.2442: Preheat combustion air with waste heat | $27,628 | $85,000 | - | - |
$27,628
-
MMBtu
|
- | |
09 | 2.1332: Convert combustion equipment to burn natural gas | $4,451 | $15,000 | - | - | - | $4,451 | |
10 | 2.7232: Replace existing hvac unit with high efficiency model | $1,832 | $8,000 |
$1,479
29,013
kWh
|
$353
-
kW-mo/yr
|
- | - | |
11 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,929 | $30,000 | - | - |
$4,929
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $75,621 | $182,400 |
$18,912
370,849
kWh
|
$2,872
-
kW-mo/yr
|
$49,386
-
MMBtu
|
$4,451 | ||
TOTAL IMPLEMENTED | $40,399 | $87,400 |
$12,209
239,413
kWh
|
$1,981
-
kW-mo/yr
|
$21,758
-
MMBtu
|
$4,451 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs