Assessment Year 2018
Principal Product Thermoformed Plastic Trays
NAICS 326112: Plastics Packaging Film and Sheet (including Laminated) Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 109
Plant Area 62,500
ft2
Annual Production 265,000,000
units
Production Hrs. Annual 6,000
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $414,294 8,577,509
kWh
Electricity Demand $64,137 21,595
kW-mo/yr
Electricity Fees $111,089 -
Natural Gas $18,997 1,965
MMBtu
TOTAL YEARLY COSTS $608,517
RECOMMENDED SAVINGS* $84,413 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $11,918

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $5,416 $1,000 $4,840
100,826
kWh
$576
-
kW-mo/yr
02 2.7142: Utilize higher efficiency lamps and/or ballasts $6,502 $19,292 $5,811
121,056
kWh
$691
-
kW-mo/yr
03 2.7232: Replace existing hvac unit with high efficiency model $15,594 $73,000 $13,991
291,470
kWh
$1,603
-
kW-mo/yr
04 2.2622: Replace existing chiller with high efficiency model $47,928 $260,000 $42,831
892,320
kWh
$5,097
-
kW-mo/yr
05 2.4226: Use / purchase optimum sized compressor $8,973 $50,000 $8,020
167,080
kWh
$953
-
kW-mo/yr
TOTAL RECOMMENDED $84,413 $403,292 $75,493
1,572,752
kWh
$8,920
-
kW-mo/yr
TOTAL IMPLEMENTED $11,918 $20,292 $10,651
221,882
kWh
$1,267
-
kW-mo/yr
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs