Assessment Year | 2018 |
---|---|
Principal Product | Miscellaneous Metal |
NAICS | 332999: All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 145 |
Plant Area |
110,000
ft2
|
Annual Production | 100,000
ton
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $54,920 | 815,040 |
kWh
|
$0.067 |
Electricity Demand | $14,827 | 3,723 |
kW-mo/yr
|
$3.98 |
Electricity Fees | $9,023 | - |
|
- |
Natural Gas | $36,678 | 4,898 |
MMBtu
|
$7.49 |
TOTAL YEARLY COSTS | $115,448 | |||
RECOMMENDED SAVINGS* | $17,108 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $650 | $40 |
$531
7,916
kWh
|
$120
-
kW-mo/yr
|
- | - | |
02 | 2.4221: Install compressor air intakes in coolest locations | $508 | $1,000 |
$412
6,142
kWh
|
$96
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,239 | $14,500 |
$4,264
63,648
kWh
|
$975
-
kW-mo/yr
|
- | - | |
04 | 2.1224: Replace boiler | $6,378 | $28,000 | - | - |
$1,378
-
MMBtu
|
$5,000 | |
05 | 2.7232: Replace existing hvac unit with high efficiency model | $4,333 | $19,000 |
$3,473
51,840
kWh
|
$860
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $17,108 | $62,540 |
$8,680
129,546
kWh
|
$2,050
-
kW-mo/yr
|
$1,378
-
MMBtu
|
$5,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs