| Assessment Year | 2018 |
|---|---|
| Principal Product | Concrete Barriers |
| NAICS | 327390: Other Concrete Product Manufacturing |
| SIC | 3271: Concrete Block and Brick |
| Sales Range | $10 M to 50M |
| # of Employees | 22 |
| Plant Area |
67,000
ft2
|
| Annual Production | 15,000,000
pieces
|
| Production Hrs. Annual | 5,200
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $30,035 | 512,700 |
kWh
|
$0.059 |
| Electricity Demand | $9,813 | 1,920 |
kW-mo/yr
|
$5.11 |
| Electricity Fees | $10,924 | - |
|
- |
| Natural Gas | $108,219 | 10,276 |
MMBtu
|
$10.53 |
| LPG | $56,411 | 6,781 |
MMBtu
|
$8.32 |
| TOTAL YEARLY COSTS | $215,402 | |||
| RECOMMENDED SAVINGS* | $27,822 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,359 | $1,000 |
$6,308
106,917
kWh
|
$1,051
-
kW-mo/yr
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,794 | $850 |
$1,318
22,344
kWh
|
$476
-
kW-mo/yr
|
- | |
| 03 | 2.2437: Recover waste heat from equipment | $3,012 | $4,000 | - | - |
$3,012
-
MMBtu
|
|
| 04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,674 | $12,500 |
$5,008
84,886
kWh
|
$1,666
-
kW-mo/yr
|
- | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,889 | $7,500 |
$3,332
56,477
kWh
|
$557
-
kW-mo/yr
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,295 | $9,500 |
$3,682
62,400
kWh
|
$613
-
kW-mo/yr
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $799 | $4,000 |
$687
11,638
kWh
|
$112
-
kW-mo/yr
|
- | |
| TOTAL RECOMMENDED | $27,822 | $39,350 |
$20,335
344,662
kWh
|
$4,475
-
kW-mo/yr
|
$3,012
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs