ITAC Assessment: LE0452
ITAC logo
ITAC Assessment: LE0452
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2018
Principal Product Juice and tea
NAICS 312111: Soft Drink Manufacturing
SIC 2086: Bottled and Canned Soft Drinks and Carbonated Waters
Sales Range $10
M
to 50
M
# of Employees 119
Plant Area 353,705
ft2
Annual Production 20,000,000
units
Production Hrs. Annual 5,400
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $540,279 10,258,159
kWh
Electricity Demand $60,002 25,027
kW-mo/yr
Electricity Fees $52,432 -
Natural Gas $659,269 133,547
MMBtu
TOTAL YEARLY COSTS $1,311,982
RECOMMENDED SAVINGS* $240,094 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $7,430 $1,000 $6,751
127,375
kWh
$679
-
kW-mo/yr
- -
02 2.4111: Utilize energy-efficient belts and other improved mechanisms $2,260 $600 $2,166
40,873
kWh
$94
-
kW-mo/yr
- -
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $7,616 $17,500 $6,764
127,620
kWh
$852
-
kW-mo/yr
- -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $16,984 $45,750 $15,835
298,771
kWh
$1,150
-
kW-mo/yr
- -
05 2.1233: Analyze flue gas for proper air/fuel ratio $40,671 $115,000 - - $40,671
-
MMBtu
-
06 2.4226: Use / purchase optimum sized compressor $155,577 $500,000 $5,577
105,222
kWh
- - $150,000
07 2.7142: Utilize higher efficiency lamps and/or ballasts $2,026 $9,190 $2,026
38,220
kWh
- - -
08 2.7232: Replace existing hvac unit with high efficiency model $6,475 $30,000 $6,096
115,024
kWh
$379
-
kW-mo/yr
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $1,055 $5,250 $935
17,640
kWh
$120
-
kW-mo/yr
- -
TOTAL RECOMMENDED $240,094 $724,290 $46,150
870,745
kWh
$3,274
-
kW-mo/yr
$40,671
-
MMBtu
$150,000
TOTAL IMPLEMENTED - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs