Assessment Year 2017
Principal Product Water Pollution Control Plant
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range less than $500
k
# of Employees 125
Plant Area 4,200,000
ft2
Annual Production 60,225,000
units
Production Hrs. Annual 8,736
hrs
Location (State) Pennsylvania

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $4,388,693 66,028,188
kWh
Electricity Demand $628,177 106,595
kW-mo/yr
Electricity Fees $262,150 -
Other Gas $1,324,239 238,817
MMBtu
TOTAL YEARLY COSTS $6,603,259
RECOMMENDED SAVINGS* $481,808 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $151,787

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.1233: Analyze flue gas for proper air/fuel ratio $33,075 $24,000 - - $33,075
-
MMBtu
02 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $207,824 $260,000 $185,130
2,805,002
kWh
$22,694
-
kW-mo/yr
-
03 2.4221: Install compressor air intakes in coolest locations $1,101 $1,500 $954
14,446
kWh
$147
-
kW-mo/yr
-
04 2.4133: Use most efficient type of electric motors $5,736 $14,000 $5,224
79,144
kWh
$512
-
kW-mo/yr
-
05 2.4133: Use most efficient type of electric motors $55,121 $144,000 $49,101
743,958
kWh
$6,020
-
kW-mo/yr
-
06 2.4133: Use most efficient type of electric motors $88,021 $265,000 $78,408
1,188,005
kWh
$9,613
-
kW-mo/yr
-
07 2.7232: Replace existing hvac unit with high efficiency model $78,911 $270,000 $70,294
1,065,064
kWh
$8,617
-
kW-mo/yr
-
08 2.4133: Use most efficient type of electric motors $12,019 $59,000 $9,286
140,701
kWh
$2,733
-
kW-mo/yr
-
TOTAL RECOMMENDED $481,808 $1,037,500 $398,397
6,036,320
kWh
$50,336
-
kW-mo/yr
$33,075
-
MMBtu
TOTAL IMPLEMENTED $151,787 $487,000 $133,905
2,028,867
kWh
$17,882
-
kW-mo/yr
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs