Assessment Year | 2016 |
---|---|
Principal Product | Commercial Refrigerators |
NAICS | 333415: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen |
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 85 |
Plant Area |
69,000
ft2
|
Annual Production | 2,400
pieces
|
Production Hrs. Annual | 2,808
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $65,893 | 810,476 |
kWh
|
$0.081 |
Electricity Demand | $14,410 | 2,664 |
kW-mo/yr
|
$5.41 |
Electricity Fees | $6,338 | - |
|
- |
Natural Gas | $21,083 | 1,736 |
MMBtu
|
$12.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $31,943 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,939 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,317 | $46 |
$1,014
12,513
kWh
|
$303
-
kW-mo/yr
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,844 | $1,000 |
$2,193
27,075
kWh
|
$651
-
kW-mo/yr
|
- | |
03 | 2.4221: Install compressor air intakes in coolest locations | $715 | $500 |
$553
6,823
kWh
|
$162
-
kW-mo/yr
|
- | |
04 | 2.2437: Recover waste heat from equipment | $1,687 | $1,868 | - | - |
$1,687
-
MMBtu
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,602 | $25,000 |
$5,271
65,074
kWh
|
$1,331
-
kW-mo/yr
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,120 | $22,015 |
$4,281
52,853
kWh
|
$839
-
kW-mo/yr
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $13,659 | $62,300 |
$10,867
134,160
kWh
|
$2,792
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $31,943 | $112,729 |
$24,178
298,498
kWh
|
$6,078
-
kW-mo/yr
|
$1,687
-
MMBtu
|
||
TOTAL IMPLEMENTED | $28,939 | $110,815 |
$23,165
285,985
kWh
|
$5,775
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs