Assessment Year | 2010 |
---|---|
Principal Product | fiberglass bathtubs and showers |
NAICS | 326191: Plastics Plumbing Fixture Manufacturing |
SIC | 3088: Plastics Plumbing Fixtures |
Sales Range | $10 M to 50M |
# of Employees | 73 |
Plant Area |
110,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $165,671 | 2,461,200 |
kWh
|
$0.067 |
Electricity Demand | $25,975 | 5,932 |
kW-mo/yr
|
$4.38 |
Natural Gas | $323,834 | 24,654 |
MMBtu
|
$13.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $20,873 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,961 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,619 | $5,856 |
$7,711
115,087
kWh
|
$2,908
-
kW-mo/yr
|
- | |
02 | 2.7447: Install vinyl strip / high speed / air curtain doors | $1,760 | $5,000 | - | - |
$1,760
-
MMBtu
|
|
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,665 | $1,768 |
$1,186
17,697
kWh
|
$479
-
kW-mo/yr
|
- | |
04 | 2.4112: Install soft-start to eliminate nuisance trips | $1,340 | $5,200 | - |
$1,340
-
kW-mo/yr
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $878 | $2,338 |
$501
7,485
kWh
|
$377
-
kW-mo/yr
|
- | |
06 | 2.7135: Install occupancy sensors | $455 | $420 |
$455
6,786
kWh
|
- | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $418 | $182 |
$418
6,248
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,738 | $17,123 |
$2,725
40,092
kWh
|
$1,013
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $20,873 | $37,887 |
$12,996
193,395
kWh
|
$6,117
-
kW-mo/yr
|
$1,760
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,961 | $4,288 |
$2,105
31,430
kWh
|
$856
-
kW-mo/yr
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs