Assessment Year | 2007 |
---|---|
Principal Product | Aluminum powder |
NAICS | 331314: Secondary Smelting and Alloying of Aluminum |
SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 19 |
Plant Area |
75,000
ft2
|
Annual Production | 100,000
units
|
Production Hrs. Annual | 8,400
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $290,817 | 5,593,200 |
kWh
|
$0.052 |
Electricity Demand | $82,020 | 11,051 |
kW-mo/yr
|
$7.42 |
Natural Gas | $499,782 | 40,409 |
MMBtu
|
$12.37 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $332,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $35,753 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $196,792 | $500 | - | - | - | $196,792 | |
02 | 2.4226: Use / purchase optimum sized compressor | $71,526 | $75,000 |
$17,855
343,361
kWh
|
$3,671
-
kW-mo/yr
|
- | $50,000 | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,454 | $12,000 |
$14,554
285,367
kWh
|
$2,900
-
kW-mo/yr
|
- | - | |
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $15,461 | $20 |
$13,602
261,571
kWh
|
$1,859
-
kW-mo/yr
|
- | - | |
05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $8,661 | $100 |
$7,300
135,189
kWh
|
$1,361
-
kW-mo/yr
|
- | - | |
06 | 2.2437: Recover waste heat from equipment | $7,137 | $5,000 | - | - |
$7,137
-
MMBtu
|
- | |
07 | 2.4221: Install compressor air intakes in coolest locations | $6,155 | $1,500 |
$4,826
92,802
kWh
|
$1,329
-
kW-mo/yr
|
- | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,476 | $150 |
$4,549
87,479
kWh
|
$927
-
kW-mo/yr
|
- | - | |
09 | 2.3134: Shift from daytime to nighttime operation | $3,985 | $300 | - |
$3,985
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $332,647 | $94,570 |
$62,686
1,205,769
kWh
|
$16,032
-
kW-mo/yr
|
$7,137
-
MMBtu
|
$246,792 | ||
TOTAL IMPLEMENTED | $35,753 | $1,770 |
$30,277
577,041
kWh
|
$5,476
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs