| Assessment Year | 2007 |
|---|---|
| Principal Product | Manufactured Homes |
| NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
| SIC | 2451: Mobile Homes |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
150,000
ft2
|
| Annual Production | 850
pieces
|
| Production Hrs. Annual | 2,160
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $66,141 | 942,000 |
kWh
|
$0.070 |
| Electricity Demand | $38,161 | 4,285 |
kW-mo/yr
|
$8.91 |
| LPG | $76,207 | 5,525 |
MMBtu
|
$13.79 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $58,769 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $13,092 | $6,400 | - | - |
$13,092
-
MMBtu
|
- | |
| 02 | 2.7231: Use radiant heater for spot heating | $12,411 | $18,750 | - | - |
$12,411
-
MMBtu
|
- | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $9,871 | $10,000 |
$299
4,276
kWh
|
$4,572
-
kW-mo/yr
|
- | $5,000 | |
| 04 | 2.7313: Recycle air for heating, ventilation and air conditioning | $6,874 | $5,000 | - | - |
$6,874
-
MMBtu
|
- | |
| 05 | 2.3132: Recharge batteries on during off-peak demand periods | $767 | $150 | - |
$767
-
kW-mo/yr
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,367 | $40,684 |
$9,231
131,878
kWh
|
$6,136
-
kW-mo/yr
|
- | - | |
| 07 | 2.7135: Install occupancy sensors | $387 | $1,400 |
$387
5,526
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $58,769 | $82,384 |
$9,917
141,680
kWh
|
$11,475
-
kW-mo/yr
|
$32,377
-
MMBtu
|
$5,000 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | LPG Savings | One-time Revenue or Avoided Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs