Assessment Year | 2006 |
---|---|
Principal Product | specialty gas mixtures |
NAICS | 325120: Industrial Gas Manufacturing |
SIC | 2813: Industrial Gases |
Sales Range | $50 M to 100M |
# of Employees | 125 |
Plant Area |
50,000
ft2
|
Annual Production | 60,000
pieces
|
Production Hrs. Annual | 4,992
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $174,593 | 1,877,600 |
kWh
|
$0.093 |
Electricity Demand | $25,294 | 4,173 |
kW-mo/yr
|
$6.06 |
Natural Gas | $22,475 | 1,879 |
MMBtu
|
$11.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,906 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.7447: Install vinyl strip / high speed / air curtain doors | $10,350 | $2,400 | - | - |
$10,350
-
MMBtu
|
|
02 | 2.7233: Use properly designed and sized hvac equipment | $9,950 | $2,250 |
$9,950
107,016
kWh
|
- | - | |
03 | 2.3134: Shift from daytime to nighttime operation | $9,817 | - | - |
$9,817
-
kW-mo/yr
|
- | |
04 | 2.6218: Turn off equipment when not in use | $6,528 | - |
$6,528
70,200
kWh
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $1,758 | $900 |
$1,758
18,900
kWh
|
- | - | |
06 | 2.2511: Insulate bare equipment | $959 | $200 |
$959
10,361
kWh
|
- | - | |
07 | 2.7135: Install occupancy sensors | $2,282 | $1,500 |
$2,282
24,534
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,262 | $13,497 |
$3,257
35,027
kWh
|
$1,005
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $45,906 | $20,747 |
$24,734
266,038
kWh
|
$10,822
-
kW-mo/yr
|
$10,350
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs