Assessment Year | 2005 |
---|---|
Principal Product | Water Activated Gummed Sealing Tapes |
NAICS | 322220: Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2641: |
Sales Range | $10 M to 50M |
# of Employees | 63 |
Plant Area |
100,000
ft2
|
Annual Production | 151,804
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Delaware |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $84,462 | 2,201,831 |
kWh
|
$0.038 |
Electricity Demand | $68,760 | 6,293 |
kW-mo/yr
|
$10.93 |
Electricity Fees | $683 | - |
|
- |
Natural Gas | $412,387 | 34,914 |
MMBtu
|
$11.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $107,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $53,446 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.5111: Convert from indirect to direct fired systems | $52,318 | $23,385 | - | - |
$52,318
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $23,185 | $7,550 | - | - |
$23,185
-
MMBtu
|
|
03 | 2.7231: Use radiant heater for spot heating | $19,652 | $12,710 | - | - |
$19,652
-
MMBtu
|
|
04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,558 | $3,000 | - |
$6,558
-
kW-mo/yr
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,348 | $2,355 |
$1,498
39,407
kWh
|
$850
-
kW-mo/yr
|
- | |
06 | 2.4226: Use / purchase optimum sized compressor | $1,667 | $1,070 |
$971
25,552
kWh
|
$696
-
kW-mo/yr
|
- | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,128 | $16,472 |
$778
20,470
kWh
|
$350
-
kW-mo/yr
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $384 | $300 |
$229
6,025
kWh
|
$155
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $107,240 | $66,842 |
$3,476
91,454
kWh
|
$8,609
-
kW-mo/yr
|
$95,155
-
MMBtu
|
||
TOTAL IMPLEMENTED | $53,446 | $39,857 |
$778
20,470
kWh
|
$350
-
kW-mo/yr
|
$52,318
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs