Assessment Year | 2005 |
---|---|
Principal Product | Acrylic Polymer |
NAICS | 325211: Plastics Material and Resin Manufacturing |
SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
Sales Range | $10 M to 50M |
# of Employees | 60 |
Plant Area |
65,000
ft2
|
Annual Production | 1,500,000
lb
|
Production Hrs. Annual | 5,640
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $242,399 | 3,281,100 |
kWh
|
$0.074 |
Electricity Demand | $47,365 | 7,752 |
kW-mo/yr
|
$6.11 |
Natural Gas | $74,703 | 6,878 |
MMBtu
|
$10.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $289,684 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $73,108 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.3415: Use a fossil fuel engine to cogenerate electricity or motive power; and utilize heat | $214,649 | $548,400 |
$181,197
2,448,606
kWh
|
$33,452
-
kW-mo/yr
|
- | - | - | |
02 | 2.4222: Install adequate dryers on air lines to eliminate blowdown | $30,000 | $2,500 | - | - | - | - | $30,000 | |
03 | 4.423: Move product using mechanical means | $25,000 | $460 | - | - | - | $25,000 | - | |
04 | 2.1233: Analyze flue gas for proper air/fuel ratio | $5,745 | $1,250 | - | - |
$5,745
-
MMBtu
|
- | - | |
05 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,758 | $2,500 | - |
$4,758
-
kW-mo/yr
|
- | - | - | |
06 | 2.7496: Install partitions to reduce size of conditioned space | $3,676 | $1,000 | - | - |
$3,676
-
MMBtu
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,869 | $750 |
$2,869
38,773
kWh
|
- | - | - | - | |
08 | 2.6218: Turn off equipment when not in use | $1,927 | $450 |
$1,927
26,039
kWh
|
- | - | - | - | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,060 | $145 |
$886
11,974
kWh
|
$174
-
kW-mo/yr
|
- | - | - | |
TOTAL RECOMMENDED | $289,684 | $557,455 |
$186,879
2,525,392
kWh
|
$38,384
-
kW-mo/yr
|
$9,421
-
MMBtu
|
$25,000 | $30,000 | ||
TOTAL IMPLEMENTED | $73,108 | $8,605 |
$3,755
50,747
kWh
|
$4,932
-
kW-mo/yr
|
$9,421
-
MMBtu
|
$25,000 | $30,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs