Assessment Year 2003
Principal Product Nickel and cobalt based alloys
NAICS 331492: Secondary Smelting, Refining, and Alloying of Nonferrous Metal (except Copper and Aluminum)
SIC 3341: Secondary Smelting and Refining of Nonferrous Metals
Sales Range $50
M
to 100
M
# of Employees 125
Plant Area 115,000
ft2
Annual Production 9
lb
Production Hrs. Annual 7,344
hrs
Location (State) New Jersey

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $2,317,371 34,415,892
kWh
Electricity Demand $522,522 57,202
kW-mo/yr
Natural Gas $1,027,588 141,006
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $190,124 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $134,042

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.2442: Preheat combustion air with waste heat $114,214 $25,000 - - $114,214
-
MMBtu
02 2.2442: Preheat combustion air with waste heat $20,766 $1,500 - - $20,766
-
MMBtu
03 2.1233: Analyze flue gas for proper air/fuel ratio $19,851 $1,000 - - $19,851
-
MMBtu
04 2.1233: Analyze flue gas for proper air/fuel ratio $14,480 $5,000 - - $14,480
-
MMBtu
05 2.4221: Install compressor air intakes in coolest locations $11,003 $1,000 $9,095
135,753
kWh
$1,908
-
kW-mo/yr
-
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $8,825 - $6,580
98,214
kWh
$2,245
-
kW-mo/yr
-
07 2.1233: Analyze flue gas for proper air/fuel ratio $985 - - - $985
-
MMBtu
TOTAL RECOMMENDED $190,124 $33,500 $15,675
233,967
kWh
$4,153
-
kW-mo/yr
$170,296
-
MMBtu
TOTAL IMPLEMENTED $134,042 $26,000 $15,675
233,967
kWh
$4,153
-
kW-mo/yr
$114,214
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs