| Assessment Year | 2003 |
|---|---|
| Principal Product | Extruded Plastic Tubing |
| NAICS | 326121: Unlaminated Plastics Profile Shape Manufacturing |
| SIC | 3082: Unsupported Plastics Profile Shapes |
| Sales Range | $5 M to 10M |
| # of Employees | 80 |
| Plant Area |
48,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $54,134 | 1,027,296 |
kWh
|
$0.053 |
| Electricity Demand | $27,162 | 2,727 |
kW-mo/yr
|
$9.96 |
| Natural Gas | $20,270 | 1,808 |
MMBtu
|
$11.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $8,466 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $5,797 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7261: Install timers and/or thermostats | $1,674 | $1,050 |
$1,674
31,768
kWh
|
- | - | |
| 02 | 2.7261: Install timers and/or thermostats | $2,194 | $1,250 | - | - |
$2,194
-
MMBtu
|
|
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,635 | $1,000 |
$1,150
21,825
kWh
|
$485
-
kW-mo/yr
|
- | |
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,067 | - |
$795
15,082
kWh
|
$272
-
kW-mo/yr
|
- | |
| 05 | 2.2511: Insulate bare equipment | $862 | $119 |
$862
16,358
kWh
|
- | - | |
| 06 | 2.7135: Install occupancy sensors | $1,034 | $675 |
$1,034
19,618
kWh
|
- | - | |
| TOTAL RECOMMENDED | $8,466 | $4,094 |
$5,515
104,651
kWh
|
$757
-
kW-mo/yr
|
$2,194
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $5,797 | $2,419 |
$3,331
63,208
kWh
|
$272
-
kW-mo/yr
|
$2,194
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs