| Assessment Year | 2002 |
|---|---|
| Principal Product | Automotive/Truck Leaf Springs |
| NAICS |
n/a
|
| SIC | 3493: Steel Springs, Except Wire |
| Sales Range | $50 M to 100M |
| # of Employees | 244 |
| Plant Area |
97,000
ft2
|
| Annual Production | 9,000
pieces
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $146,672 | 2,118,600 |
kWh
|
$0.069 |
| Electricity Demand | $57,439 | 5,606 |
kW-mo/yr
|
$10.25 |
| Natural Gas | $396,900 | 71,076 |
MMBtu
|
$5.58 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $61,264 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $11,162 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $1,396 | $1,000 |
$872
20,714
kWh
|
$524
-
kW-mo/yr
|
- | |
| 02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,018 | - |
$2,018
47,938
kWh
|
- | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,005 | $100 |
$4,005
95,131
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,139 | $882 |
$3,478
82,620
kWh
|
$1,661
-
kW-mo/yr
|
- | |
| 05 | 2.7243: Improve air circulation with destratification fans / other methods | $2,495 | $7,000 | - | - |
$2,495
-
MMBtu
|
|
| 06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $9,311 | $2,000 | - |
$9,311
-
kW-mo/yr
|
- | |
| 07 | 2.2426: Use waste heat from flue gases to heat space conditioning air | $36,900 | $30,000 | - | - |
$36,900
-
MMBtu
|
|
| TOTAL RECOMMENDED | $61,264 | $40,982 |
$10,373
246,403
kWh
|
$11,496
-
kW-mo/yr
|
$39,395
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $11,162 | $982 |
$9,501
225,689
kWh
|
$1,661
-
kW-mo/yr
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs