Assessment Year | 2002 |
---|---|
Principal Product | Cordage, Storage and Organization Hardware |
NAICS |
n/a
|
SIC | 2298: Cordage and Twine |
Sales Range | $50 M to 100M |
# of Employees | 198 |
Plant Area |
269,000
ft2
|
Annual Production | 0
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $194,777 | 3,104,938 |
kWh
|
$0.063 |
Electricity Demand | $38,962 | 6,874 |
kW-mo/yr
|
$5.67 |
Natural Gas | $100,281 | 8,615 |
MMBtu
|
$11.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $85,386 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $83,739 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.8113: Purchase gas directly from a contract gas supplier | $78,742 | - | - | - | $78,742 | - | |
02 | 2.1331: Burn a less expensive grade of fuel | $1,298 | $6,000 | - | - | - | $1,298 | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $983 | - |
$635
12,646
kWh
|
$348
-
kW-mo/yr
|
- | - | |
04 | 2.7135: Install occupancy sensors | $349 | $750 |
$349
6,956
kWh
|
- | - | - | |
05 | 2.4221: Install compressor air intakes in coolest locations | $851 | $750 |
$613
12,219
kWh
|
$238
-
kW-mo/yr
|
- | - | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,163 | - |
$2,453
48,859
kWh
|
$710
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $85,386 | $7,500 |
$4,050
80,680
kWh
|
$1,296
-
kW-mo/yr
|
$78,742 | $1,298 | ||
TOTAL IMPLEMENTED | $83,739 | $750 |
$3,701
73,724
kWh
|
$1,296
-
kW-mo/yr
|
$78,742 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs