| Assessment Year | 2001 |
|---|---|
| Principal Product | Food flavorings and stabilizers |
| NAICS |
n/a
|
| SIC | 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 150 |
| Plant Area |
79,610
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 6,672
hrs
|
| Location (State) | Pennsylvania |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $215,800 | 2,538,100 |
kWh
|
$0.085 |
| Electricity Demand | $43,813 | 602 |
kW-mo/yr
|
$72.78 |
| Natural Gas | $135,712 | 22,163 |
MMBtu
|
$6.12 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $47,122 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $30,812 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4221: Install compressor air intakes in coolest locations | $993 | $200 |
$746
11,002
kWh
|
$247
-
kW-mo/yr
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,669 | - |
$2,857
42,144
kWh
|
$812
-
kW-mo/yr
|
- | |
| 03 | 2.4314: Use synthetic lubricant | $2,381 | $400 |
$1,984
29,263
kWh
|
$397
-
kW-mo/yr
|
- | |
| 04 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $6,572 | - | - |
$6,572
-
kW-mo/yr
|
- | |
| 05 | 2.2136: Install / repair insulation on steam lines | $3,057 | $1,225 | - | - |
$3,057
-
MMBtu
|
|
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $10,260 | $15,500 | - | - |
$10,260
-
MMBtu
|
|
| 07 | 2.2123: Insulate feedwater tank | $15,398 | $450 |
$14,296
210,851
kWh
|
- |
$1,102
-
MMBtu
|
|
| 08 | 2.4239: Eliminate or reduce compressed air usage | $4,792 | $768 |
$4,792
70,674
kWh
|
- | - | |
| TOTAL RECOMMENDED | $47,122 | $18,543 |
$24,675
363,934
kWh
|
$8,028
-
kW-mo/yr
|
$14,419
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $30,812 | $2,643 |
$19,834
292,527
kWh
|
$6,819
-
kW-mo/yr
|
$4,159
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs