Assessment Year | 2001 |
---|---|
Principal Product | Carbon,stainless steel, and nickel base casting |
NAICS |
n/a
|
SIC | 3325: Steel Foundries, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 30 |
Plant Area |
26,000
ft2
|
Annual Production | 480
ton
|
Production Hrs. Annual | 2,040
hrs
|
Location (State) | Pennsylvania |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $90,985 | 1,286,880 |
kWh
|
$0.071 |
Electricity Demand | $32,761 | 3,790 |
kW-mo/yr
|
$8.64 |
Natural Gas | $4,905 | 523 |
MMBtu
|
$9.38 |
Other Gas | $2,629 | - |
|
- |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,180 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2623: Minimize condenser cooling water temperature | $2,453 | $245 | - | - |
$2,453
-
MMBtu
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $674 | - |
$343
7,612
kWh
|
$331
-
kW-mo/yr
|
- | - | |
03 | 2.1331: Burn a less expensive grade of fuel | $301 | - | - | - | - |
$301
-
MMBtu
|
|
04 | 2.7447: Install vinyl strip / high speed / air curtain doors | $2,872 | $850 | - | - |
$2,872
-
MMBtu
|
- | |
05 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $4,880 | $1,200 | - | - |
$4,880
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $11,180 | $2,295 |
$343
7,612
kWh
|
$331
-
kW-mo/yr
|
$10,205
-
MMBtu
|
$301
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs