Assessment Year | 2001 |
---|---|
Principal Product | Polyester Labels |
NAICS |
n/a
|
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 27 |
Plant Area |
22,500
ft2
|
Annual Production | 14,900
thousand feet
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | New Jersey |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $61,217 | 587,740 |
kWh
|
$0.10 |
Electricity Demand | $15,162 | 314 |
kW-mo/yr
|
$48.29 |
Natural Gas | $33,743 | 5,089 |
MMBtu
|
$6.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,289 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,401 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7243: Improve air circulation with destratification fans / other methods | $1,815 | $1,500 | - | - |
$1,815
-
MMBtu
|
- | |
02 | 2.4221: Install compressor air intakes in coolest locations | $393 | $550 |
$285
3,455
kWh
|
$108
-
kW-mo/yr
|
- | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $2,065 | $2,500 | - |
$2,065
-
kW-mo/yr
|
- | - | |
04 | 2.4312: Improve lubrication practices | $378 | $400 |
$321
3,899
kWh
|
$57
-
kW-mo/yr
|
- | - | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $630 | - |
$536
6,504
kWh
|
$94
-
kW-mo/yr
|
- | - | |
06 | 2.2153: Close off unneeded steam lines | $7,496 | $7,200 | - | - | - |
$7,496
-
gal
|
|
07 | 2.2515: Use optimum thickness insulation | $4,512 | $5,280 |
$735
8,933
kWh
|
$157
-
kW-mo/yr
|
$3,620
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $17,289 | $17,430 |
$1,877
22,791
kWh
|
$2,481
-
kW-mo/yr
|
$5,435
-
MMBtu
|
$7,496
-
gal
|
||
TOTAL IMPLEMENTED | $1,401 | $950 |
$1,142
13,858
kWh
|
$259
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs