Assessment Year | 2000 |
---|---|
Principal Product | wooden cabinets |
NAICS |
n/a
|
SIC | 2434: Wood Kitchen Cabinets |
Sales Range | $10 M to 50M |
# of Employees | 280 |
Plant Area |
230,000
ft2
|
Annual Production | 4,951
ton
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $172,578 | 3,342,614 |
kWh
|
$0.052 |
Electricity Demand | $55,330 | 12,600 |
kW-mo/yr
|
$4.39 |
Natural Gas | $1,462 | 2,156 |
MMBtu
|
$0.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $39,620 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $36,900 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7124: Make a practice of turning off lights when not needed | $3,310 | $800 |
$1,900
49,824
kWh
|
$1,210
-
kW-mo/yr
|
$200 | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,390 | $840 |
$1,080
28,429
kWh
|
$1,310
-
kW-mo/yr
|
- | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,020 | $920 |
$460
12,309
kWh
|
$560
-
kW-mo/yr
|
- | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $680 | $280 |
$310
7,913
kWh
|
$370
-
kW-mo/yr
|
- | - | |
05 | 4.445: Install equipment to move product | $31,200 | $2,780 | - | - | $31,200 | - | |
06 | 4.131: Modify process to reduce material use/cost | $1,020 | $500 | - | - | - | $1,020 | |
TOTAL RECOMMENDED | $39,620 | $6,120 |
$3,750
98,475
kWh
|
$3,450
-
kW-mo/yr
|
$31,400 | $1,020 | ||
TOTAL IMPLEMENTED | $36,900 | $4,420 |
$2,980
78,253
kWh
|
$2,520
-
kW-mo/yr
|
$31,400 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs