| Assessment Year | 1998 |
|---|---|
| Principal Product | baking mixes |
| NAICS |
n/a
|
| SIC | 2045: Prepared Flour Mixes and Doughs |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
110,000
ft2
|
| Annual Production | 87,000,000
lb
|
| Production Hrs. Annual | 4,368
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $192,926 | 9,279,895 |
kWh
|
$0.021 |
| Electricity Demand | $60,733 | 11,627 |
kW-mo/yr
|
$5.22 |
| Natural Gas | $33,350 | 5,549 |
MMBtu
|
$6.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $81,840 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $7,360 | $8,900 | n/a | - | - | $7,360 | - | - | - | - |
| 02 | 2.2511: Insulate bare equipment | $2,180 | $1,820 | n/a | - | - | - |
$2,180
-
MMBtu
|
- | - | - |
| 03 | 2.4221: Install compressor air intakes in coolest locations | $1,100 | $930 | n/a |
$710
34,291
kWh
|
$390
-
kW-mo/yr
|
- | - | - | - | - |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $790 | $820 | n/a |
$140
7,034
kWh
|
$100
-
kW-mo/yr
|
- | - | - | $550 | - |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $310 | $150 | n/a |
$180
8,792
kWh
|
$130
-
kW-mo/yr
|
- | - | - | - | - |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $250 | $430 | n/a |
$40
2,052
kWh
|
$10
-
kW-mo/yr
|
- | - | - | $200 | - |
| 07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $10,490 | $8,000 | n/a | - | - | - | - |
$11,630
-
lb
|
$(-1,140.0) | - |
| 08 | 4.122: Develop standard procedures to improve internal yields | $59,360 | $440 | n/a | - | - | - | - | - | - | $59,360 |
| TOTAL RECOMMENDED | $81,840 | $21,490 |
$1,070
52,169
kWh
|
$630
-
kW-mo/yr
|
$7,360 |
$2,180
-
MMBtu
|
$11,630
-
lb
|
$(-390.0) | $59,360 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs