| Assessment Year | 1997 |
|---|---|
| Principal Product | multiwall paper bags |
| NAICS |
n/a
|
| SIC | 2693: |
| Sales Range | $50 M to 100M |
| # of Employees | 300 |
| Plant Area |
128,900
ft2
|
| Annual Production | 33,000
ton
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $258,387 | 5,182,591 |
kWh
|
$0.050 |
| Electricity Demand | $60,518 | 11,880 |
kW-mo/yr
|
$5.09 |
| Natural Gas | $127,604 | 22,586 |
MMBtu
|
$5.65 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $77,650 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $74,040 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $5,850 | $8,570 |
$5,110
102,286
kWh
|
$740
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.4221: Install compressor air intakes in coolest locations | $4,530 | $410 |
$3,890
77,960
kWh
|
$640
-
kW-mo/yr
|
- | - | - | |
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,350 | $380 |
$3,740
74,736
kWh
|
$610
-
kW-mo/yr
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,220 | $15,180 |
$3,630
72,685
kWh
|
$590
-
kW-mo/yr
|
- | - | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,320 | $500 |
$2,040
40,739
kWh
|
$280
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $730 | $1,240 |
$1,160
23,154
kWh
|
$130
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.2511: Insulate bare equipment | $560 | $400 | - | - | - | - | - | |
| 08 | 3.4111: Use closed cycle process to minimize waste water production | $5,090 | $12,000 |
$(-110.0)
(-2,052)
kWh
|
$(-20.0)
-
kW-mo/yr
|
$2,960
-
Tgal
|
- |
$2,260
-
Tgal
|
|
| 09 | 4.711: Initiate a total quality management program | $50,000 | $13,360 | - | - | - | $50,000 | - | |
| TOTAL RECOMMENDED | $77,650 | $52,040 |
$19,460
389,508
kWh
|
$2,970
-
kW-mo/yr
|
$2,960
-
Tgal
|
$50,000 |
$2,260
-
Tgal
|
||
| TOTAL IMPLEMENTED | $74,040 | $49,900 |
$16,260
325,615
kWh
|
$2,560
-
kW-mo/yr
|
$2,960
-
Tgal
|
$50,000 |
$2,260
-
Tgal
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | Personnel Changes Savings | Water Consumption Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs