Assessment Year 1999
Principal Product Subsurface oilwell pumps, pumping equipment
NAICS
n/a
SIC 3533: Oil and Gas Field Machinery and Equipment
Sales Range $50
M
to 100
M
# of Employees 250
Plant Area 500,000
ft2
Annual Production 72,000
pieces
Production Hrs. Annual 2,008
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $280,606 6,830,598
kWh
Electricity Demand $182,600 33,857
kW-mo/yr
Natural Gas $42,058 14,573
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $37,685 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $30,405

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Solid Waste (non-haz) Savings Personnel Changes Savings
01 4.454: Modify startup/shutdown times $25,130 - - - $25,130
02 3.7198: Reduce / eliminate use of disposable product $5,910 $150 - $5,910
-
lb
-
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,285 $1,400 $365
9,672
kWh
- $1,920
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,300 $500 $2,300
60,375
kWh
- -
05 2.7124: Make a practice of turning off lights when not needed $570 $150 $570
14,947
kWh
- -
06 2.4221: Install compressor air intakes in coolest locations $540 $600 $540
14,361
kWh
- -
07 2.4314: Use synthetic lubricant $470 - $470
12,309
kWh
- -
08 2.7124: Make a practice of turning off lights when not needed $360 $1,480 $360
9,672
kWh
- -
09 2.7124: Make a practice of turning off lights when not needed $120 - $120
3,224
kWh
- -
TOTAL RECOMMENDED $37,685 $4,280 $4,725
124,560
kWh
$5,910
-
lb
$27,050
TOTAL IMPLEMENTED $30,405 $2,050 $3,355
88,218
kWh
- $27,050
Yearly Savings* Imp'd Cost* Electricity Usage Savings Solid Waste (non-haz) Savings Personnel Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs