| Assessment Year | 1996 |
|---|---|
| Principal Product | tractor enclosures/rollbars |
| NAICS |
n/a
|
| SIC | 3523: Farm Machinery and Equipment |
| Sales Range | $5 M to 10M |
| # of Employees | 95 |
| Plant Area |
126,600
ft2
|
| Annual Production | 8,000
pieces
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $67,148 | 1,101,114 |
kWh
|
$0.061 |
| Electricity Demand | $9,407 | 3,031 |
kW-mo/yr
|
$3.10 |
| Natural Gas | $72,586 | 15,253 |
MMBtu
|
$4.76 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $52,409 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $45,067 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings |
|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7231: Use radiant heater for spot heating | $23,445 | $31,940 |
$10,845
95,545
kWh
|
- | - | - | - | $12,600 | |
| 02 | 2.1122: Re-size charging openings or add a movable door on equipment | $16,546 | $12,960 |
$(-553.0)
(-15,240)
kWh
|
$(-276.0)
-
kW-mo/yr
|
$17,375
-
MMBtu
|
- | - | - | |
| 03 | 2.2414: Use waste heat from hot flue gases to preheat | $4,661 | $6,950 | - | - |
$4,661
-
MMBtu
|
- | - | - | |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,223 | $302 |
$1,992
43,083
kWh
|
$231
-
kW-mo/yr
|
- | - | - | - | |
| 05 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $2,036 | $3,500 | - | - | - |
$2,036
-
gal
|
- | - | |
| 06 | 2.2511: Insulate bare equipment | $1,182 | $139 |
$1,182
10,551
kWh
|
- | - | - | - | - | |
| 07 | 2.7135: Install occupancy sensors | $731 | $700 |
$615
16,999
kWh
|
$116
-
kW-mo/yr
|
- | - | - | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $645 | $470 |
$583
12,016
kWh
|
$62
-
kW-mo/yr
|
- | - | - | - | |
| 09 | 2.4314: Use synthetic lubricant | $418 | $105 |
$357
7,034
kWh
|
$35
-
kW-mo/yr
|
- | - | $26 | - | |
| 10 | 2.4133: Use most efficient type of electric motors | $387 | $688 |
$356
7,034
kWh
|
$31
-
kW-mo/yr
|
- | - | - | - | |
| 11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $135 | $119 |
$113
3,224
kWh
|
$22
-
kW-mo/yr
|
- | - | - | - | |
| TOTAL RECOMMENDED | $52,409 | $57,873 |
$15,490
180,246
kWh
|
$221
-
kW-mo/yr
|
$22,036
-
MMBtu
|
$2,036
-
gal
|
$26 | $12,600 | ||
| TOTAL IMPLEMENTED | $45,067 | $46,953 |
$14,907
168,230
kWh
|
$159
-
kW-mo/yr
|
$17,375
-
MMBtu
|
- | $26 | $12,600 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs