Assessment Year | 1996 |
---|---|
Principal Product | Potato Chips, Snack Foods |
NAICS |
n/a
|
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 82 |
Plant Area |
50,685
ft2
|
Annual Production | 6,500,000
lb
|
Production Hrs. Annual | 2,080
hrs
|
Location (State) | Nebraska |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,242 | 1,327,374 |
kWh
|
$0.023 |
Electricity Demand | $35,287 | 4,368 |
kW-mo/yr
|
$8.08 |
Natural Gas | $126,739 | 38,431 |
MMBtu
|
$3.30 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,230 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,281 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $5,949 | $26,000 | - | - |
$2,549
-
MMBtu
|
$4,400
-
lb
|
- | $(-1,000.0) | - | |
02 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,591 | $1,000 | - | - |
$4,591
-
MMBtu
|
- | - | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,835 | $10,180 |
$711
31,067
kWh
|
$1,124
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,711 | $1,800 |
$846
37,222
kWh
|
$865
-
kW-mo/yr
|
- | - | - | - | - | |
05 | 2.4133: Use most efficient type of electric motors | $1,034 | $3,130 |
$313
13,775
kWh
|
$721
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $813 | $155 |
$755
33,118
kWh
|
$58
-
kW-mo/yr
|
- | - | - | - | - | |
07 | 2.4221: Install compressor air intakes in coolest locations | $592 | $165 |
$396
17,292
kWh
|
$196
-
kW-mo/yr
|
- | - | - | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $433 | $663 |
$129
5,569
kWh
|
$304
-
kW-mo/yr
|
- | - | - | - | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $272 | $480 |
$61
2,638
kWh
|
$29
-
kW-mo/yr
|
- | - | $140 | - | $42 | |
TOTAL RECOMMENDED | $17,230 | $43,573 |
$3,211
140,681
kWh
|
$3,297
-
kW-mo/yr
|
$7,140
-
MMBtu
|
$4,400
-
lb
|
$140 | $(-1,000.0) | $42 | ||
TOTAL IMPLEMENTED | $11,281 | $17,573 |
$3,211
140,681
kWh
|
$3,297
-
kW-mo/yr
|
$4,591
-
MMBtu
|
- | $140 | - | $42 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs