| Assessment Year | 1995 |
|---|---|
| Principal Product | Truck shells |
| NAICS |
n/a
|
| SIC | 3083: Laminated Plastics Plate, Sheet, and Profile Shapes |
| Sales Range | $5 M to 10M |
| # of Employees | 23 |
| Plant Area |
64,000
ft2
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 2,385
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $77,528 | 920,281 |
kWh
|
$0.084 |
| Natural Gas | $7,832 | 1,446 |
MMBtu
|
$5.42 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $16,190 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $13,240 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.3137: Use power during off-peak periods | $12,650 | - |
$12,650
-
kWh
|
|
| 02 | 2.3137: Use power during off-peak periods | $1,770 | - |
$1,770
-
kWh
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $560 | $40 |
$560
6,155
kWh
|
|
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $430 | - |
$430
13,189
kWh
|
|
| 05 | 2.7134: Use photocell controls | $330 | $300 |
$330
4,689
kWh
|
|
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $260 | $200 |
$260
8,206
kWh
|
|
| 07 | 2.4221: Install compressor air intakes in coolest locations | $190 | $70 |
$190
2,052
kWh
|
|
| TOTAL RECOMMENDED | $16,190 | $610 |
$16,190
34,291
kWh
|
||
| TOTAL IMPLEMENTED | $13,240 | $500 |
$13,240
12,895
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs