ITAC Assessment: KU0450
ITAC logo
ITAC Assessment: KU0450
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1995
Principal Product Point of purchase displays
NAICS
n/a
SIC 2542: Office and Store Fixtures, Partitions, Shelving, and Lockers, Except Wood
Sales Range $5
M
to 10
M
# of Employees 350
Plant Area 303,886
ft2
Annual Production 41,000
thousand feet
Production Hrs. Annual 6,600
hrs
Location (State) Kansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $174,404 3,201,641
kWh
Natural Gas $47,886 9,545
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $28,825 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,540

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Water Disposal Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $11,232 $34,320 $9,087
166,764
kWh
- - $2,145
02 2.7134: Use photocell controls $3,753 $420 $3,753
68,875
kWh
- - -
03 2.7135: Install occupancy sensors $1,214 $1,970 $1,214
22,274
kWh
- - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $391 $660 $160
2,931
kWh
- - $231
05 3.4155: Meter waste water $2,463 $500 - - $2,463
-
Tgal
-
06 2.4221: Install compressor air intakes in coolest locations $1,821 $232 $1,821
33,411
kWh
- - -
07 2.4231: Reduce the pressure of compressed air to the minimum required $1,310 $180 $1,310
24,033
kWh
- - -
08 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,246 $165 $1,246
22,860
kWh
- - -
09 2.2511: Insulate bare equipment $1,004 $2,184 - $1,004
-
MMBtu
- -
10 3.4113: Treat and reuse rinse waters $990 $3,850 - - $990
-
Tgal
-
11 2.3212: Optimize plant power factor $2,417 $4,200 $2,417
-
kWh
- - -
12 2.1233: Analyze flue gas for proper air/fuel ratio $984 $150 - $984
-
MMBtu
- -
TOTAL RECOMMENDED $28,825 $48,831 $21,008
341,148
kWh
$1,988
-
MMBtu
$3,453
-
Tgal
$2,376
TOTAL IMPLEMENTED $3,540 $495 $2,556
46,893
kWh
$984
-
MMBtu
- -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Water Disposal Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs