Assessment Year | 1994 |
---|---|
Principal Product | corrugated cardboard |
NAICS |
n/a
|
SIC | 2653: Corrugated and Solid Fiber Boxes |
Sales Range | $10 M to 50M |
# of Employees | 110 |
Plant Area |
138,400
ft2
|
Annual Production | 500,000
thousand feet
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $168,679 | 3,799,238 |
kWh
|
$0.044 |
Natural Gas | $140,760 | 51,514 |
MMBtu
|
$2.73 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $22,698 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $17,468 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $7,585 | $33,602 |
$7,585
170,868
kWh
|
- | |
02 | 2.2511: Insulate bare equipment | $3,928 | $2,300 | - |
$3,928
-
MMBtu
|
|
03 | 2.4133: Use most efficient type of electric motors | $2,732 | $5,282 |
$2,732
61,547
kWh
|
- | |
04 | 2.7145: Install skylights | $3,669 | $14,540 |
$3,669
82,649
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,571 | $3,811 |
$1,571
21,981
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,197 | $2,072 |
$1,197
26,964
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $390 | $720 |
$390
3,224
kWh
|
- | |
08 | 2.4221: Install compressor air intakes in coolest locations | $1,171 | $113 |
$1,171
26,377
kWh
|
- | |
09 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $455 | $241 |
$455
10,258
kWh
|
- | |
TOTAL RECOMMENDED | $22,698 | $62,681 |
$18,770
403,868
kWh
|
$3,928
-
MMBtu
|
||
TOTAL IMPLEMENTED | $17,468 | $47,308 |
$13,540
291,618
kWh
|
$3,928
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs