| Assessment Year | 1994 |
|---|---|
| Principal Product | Polyethylene Tanks |
| NAICS |
n/a
|
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
122,000
ft2
|
| Annual Production | 9,000,000
lb
|
| Production Hrs. Annual | 6,672
hrs
|
| Location (State) | Nebraska |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $120,073 | 2,502,345 |
kWh
|
$0.048 |
| Natural Gas | $250,538 | 83,873 |
MMBtu
|
$2.99 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $104,734 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,751 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2437: Recover waste heat from equipment | $76,353 | $131,600 | - |
$76,353
-
MMBtu
|
- | |
| 02 | 2.4133: Use most efficient type of electric motors | $5,623 | $31,141 |
$5,623
117,233
kWh
|
- | - | |
| 03 | 2.7145: Install skylights | $5,343 | $14,940 |
$5,343
111,372
kWh
|
- | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,287 | $13,432 |
$5,287
110,199
kWh
|
- | - | |
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,484 | $11,400 |
$5,484
56,858
kWh
|
- | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $441 | $752 |
$441
4,982
kWh
|
- | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $465 | $299 |
$465
3,517
kWh
|
- | - | |
| 08 | 2.4221: Install compressor air intakes in coolest locations | $3,178 | $174 |
$3,178
66,237
kWh
|
- | - | |
| 09 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,645 | $150 |
$1,645
34,291
kWh
|
- | - | |
| 10 | 2.4231: Reduce the pressure of compressed air to the minimum required | $759 | $180 |
$759
15,826
kWh
|
- | - | |
| 11 | 2.8112: Combine utility meters | $156 | $10 | - | - | $156 | |
| TOTAL RECOMMENDED | $104,734 | $204,078 |
$28,225
520,515
kWh
|
$76,353
-
MMBtu
|
$156 | ||
| TOTAL IMPLEMENTED | $17,751 | $44,106 |
$17,595
298,944
kWh
|
- | $156 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs