Assessment Year | 1994 |
---|---|
Principal Product | Periodicals and books |
NAICS |
n/a
|
SIC | 2721: Periodicals: Publishing, or Publishing and Printing |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
144,000
ft2
|
Annual Production | 2,400,000
pieces
|
Production Hrs. Annual | 4,758
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,297 | 1,817,409 |
kWh
|
$0.043 |
Natural Gas | $4,783 | 1,041 |
MMBtu
|
$4.59 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $6,771 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,696 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.2623: Minimize condenser cooling water temperature | $4,888 | $2,500 |
$4,888
114,889
kWh
|
|
02 | 2.7124: Make a practice of turning off lights when not needed | $1,222 | - |
$1,222
28,722
kWh
|
|
03 | 2.7132: Install timers on light switches in little used areas | $399 | $68 |
$399
9,379
kWh
|
|
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $75 | $288 |
$75
1,758
kWh
|
|
05 | 2.4221: Install compressor air intakes in coolest locations | $187 | $260 |
$187
4,396
kWh
|
|
TOTAL RECOMMENDED | $6,771 | $3,116 |
$6,771
159,144
kWh
|
||
TOTAL IMPLEMENTED | $1,696 | $356 |
$1,696
39,859
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs