Assessment Year | 1994 |
---|---|
Principal Product | Radio Controls |
NAICS |
n/a
|
SIC | 3944: Games, Toys, and Children's Vehicles, Except Dolls and Bicycles |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
17,320
ft2
|
Annual Production | 3,300
pieces
|
Production Hrs. Annual | 2,125
hrs
|
Location (State) | Missouri |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $16,325 | 179,660 |
kWh
|
$0.091 |
Natural Gas | $4,562 | 923 |
MMBtu
|
$4.94 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $2,796 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,224 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,156 | $1,663 |
$799
8,792
kWh
|
- | $357 | |
02 | 2.7135: Install occupancy sensors | $240 | $300 |
$240
2,638
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $80 | $125 |
$80
879
kWh
|
- | - | |
04 | 2.7261: Install timers and/or thermostats | $904 | $900 | - |
$904
-
MMBtu
|
- | |
05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $229 | $477 |
$293
3,224
kWh
|
$(-64.0)
-
MMBtu
|
- | |
06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $187 | $135 |
$187
2,052
kWh
|
- | - | |
TOTAL RECOMMENDED | $2,796 | $3,600 |
$1,599
17,585
kWh
|
$840
-
MMBtu
|
$357 | ||
TOTAL IMPLEMENTED | $1,224 | $1,325 |
$320
3,517
kWh
|
$904
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs