Assessment Year | 2018 |
---|---|
Principal Product | Commercial Printing |
NAICS | 323111: Commercial Printing (except Screen and Books) |
SIC | 2759: Commercial Printing, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
100,000
ft2
|
Annual Production | 1,000
pieces
|
Production Hrs. Annual | 4,080
hrs
|
Location (State) | Arizona |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $133,433 | 1,438,276 |
kWh
|
$0.093 | |
Electricity Demand | $23,492 | 4,943 |
kW-mo/yr
|
$4.75 | |
Electricity Fees | $1,988 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $8,241 | 2,594 |
Tgal
|
$3.18 | |
TOTAL YEARLY COSTS | $167,154 | ||||
RECOMMENDED SAVINGS* | $31,344 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,280 | $31,442 |
$7,477
90,410
kWh
|
$1,803
-
kW-mo/yr
|
|
02 | 2.7132: Install timers on light switches in little used areas | $1,206 | $1,200 |
$1,206
13,991
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,408 | $260 |
$2,235
26,669
kWh
|
$173
-
kW-mo/yr
|
|
04 | 2.4224: Upgrade controls on compressors | $5,532 | $344 |
$4,640
55,976
kWh
|
$892
-
kW-mo/yr
|
|
05 | 2.7226: Use computer programs to optimize hvac performance | $12,918 | $55,000 |
$10,838
129,327
kWh
|
$2,080
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $31,344 | $88,246 |
$26,396
316,373
kWh
|
$4,948
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - |