| Assessment Year | 1992 |
|---|---|
| Principal Product | INSTANT TEA |
| NAICS |
n/a
|
| SIC | 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 40 |
| Plant Area |
n/a
|
| Annual Production | 4,800,000
lb
|
| Production Hrs. Annual | 5,592
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $839,433 | 18,896,249 |
kWh
|
$0.044 |
| Natural Gas | $801,358 | 318,063 |
MMBtu
|
$2.52 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $439,192 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $74,237 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2627: Use multiple-effect evaporators | $133,326 | $720,000 | - |
$133,326
-
MMBtu
|
- | |
| 02 | 3.6192: Use a less expensive method of waste removal | $91,322 | - |
$990
22,274
kWh
|
- | $90,332 | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $46,997 | $208,233 |
$26,678
600,528
kWh
|
$20,319
-
MMBtu
|
- | |
| 04 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $35,349 | $117,700 |
$35,349
795,721
kWh
|
- | - | |
| 05 | 2.2414: Use waste heat from hot flue gases to preheat | $29,723 | $39,435 | - |
$29,723
-
MMBtu
|
- | |
| 06 | 2.2444: Use hot process fluids to preheat incoming process fluids | $32,127 | $90,000 | - |
$32,127
-
MMBtu
|
- | |
| 07 | 2.2113: Repair or replace steam traps | $29,914 | - | - |
$25,787
-
MMBtu
|
$4,127 | |
| 08 | 2.2135: Repair and eliminate steam leaks | $5,325 | $670 | - |
$5,325
-
MMBtu
|
- | |
| 09 | 2.4133: Use most efficient type of electric motors | $3,789 | $10,400 |
$3,789
85,287
kWh
|
- | - | |
| 10 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,785 | $70,400 |
$17,785
400,352
kWh
|
- | - | |
| 11 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $6,367 | $8,000 |
$6,367
143,318
kWh
|
- | - | |
| 12 | 2.7261: Install timers and/or thermostats | $4,086 | - |
$2,357
53,048
kWh
|
$1,729
-
MMBtu
|
- | |
| 13 | 2.2511: Insulate bare equipment | $3,082 | $10,685 | - |
$3,082
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $439,192 | $1,275,523 |
$93,315
2,100,528
kWh
|
$251,418
-
MMBtu
|
$94,459 | ||
| TOTAL IMPLEMENTED | $74,237 | $111,755 |
$3,789
85,287
kWh
|
$66,321
-
MMBtu
|
$4,127 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs