Assessment Year 1992
Principal Product INSTANT TEA
NAICS
n/a
SIC 2087: Flavoring Extracts and Flavoring Syrups, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 40
Plant Area
n/a
Annual Production 4,800,000
lb
Production Hrs. Annual 5,592
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $839,433 18,896,249
kWh
Natural Gas $801,358 318,063
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $439,192 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $74,237

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.2627: Use multiple-effect evaporators $133,326 $720,000 - $133,326
-
MMBtu
-
02 3.6192: Use a less expensive method of waste removal $91,322 - $990
22,274
kWh
- $90,332
03 2.4322: Use or replace with energy efficient substitutes $46,997 $208,233 $26,678
600,528
kWh
$20,319
-
MMBtu
-
04 2.2614: Use cooling tower or economizer to replace chiller cooling $35,349 $117,700 $35,349
795,721
kWh
- -
05 2.2414: Use waste heat from hot flue gases to preheat $29,723 $39,435 - $29,723
-
MMBtu
-
06 2.2444: Use hot process fluids to preheat incoming process fluids $32,127 $90,000 - $32,127
-
MMBtu
-
07 2.2113: Repair or replace steam traps $29,914 - - $25,787
-
MMBtu
$4,127
08 2.2135: Repair and eliminate steam leaks $5,325 $670 - $5,325
-
MMBtu
-
09 2.4133: Use most efficient type of electric motors $3,789 $10,400 $3,789
85,287
kWh
- -
10 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $17,785 $70,400 $17,785
400,352
kWh
- -
11 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary $6,367 $8,000 $6,367
143,318
kWh
- -
12 2.7261: Install timers and/or thermostats $4,086 - $2,357
53,048
kWh
$1,729
-
MMBtu
-
13 2.2511: Insulate bare equipment $3,082 $10,685 - $3,082
-
MMBtu
-
TOTAL RECOMMENDED $439,192 $1,275,523 $93,315
2,100,528
kWh
$251,418
-
MMBtu
$94,459
TOTAL IMPLEMENTED $74,237 $111,755 $3,789
85,287
kWh
$66,321
-
MMBtu
$4,127
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs