Assessment Year | 1992 |
---|---|
Principal Product | DAMPERS, LOUVERS |
NAICS |
n/a
|
SIC | 3444: Sheet Metal Work |
Sales Range | $10 M to 50M |
# of Employees | 212 |
Plant Area |
n/a
|
Annual Production | 504,400
pieces
|
Production Hrs. Annual | 3,825
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,401 | 1,554,220 |
kWh
|
$0.050 |
Natural Gas | $40,680 | 9,154 |
MMBtu
|
$4.44 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $9,163 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,780 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,723 | $850 |
$3,723
74,736
kWh
|
- | - | |
02 | 2.4239: Eliminate or reduce compressed air usage | $1,986 | $300 |
$1,986
39,859
kWh
|
- | - | |
03 | 2.2511: Insulate bare equipment | $1,732 | $4,032 | - |
$1,732
-
MMBtu
|
- | |
04 | 2.6212: Turn off equipment during breaks, reduce operating time | $1,300 | $949 |
$234
4,689
kWh
|
$1,066
-
MMBtu
|
- | |
05 | 2.6232: Install set-back timers | $365 | $760 |
$365
7,327
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $57 | - |
$102
2,052
kWh
|
- | $(-45.0) | |
TOTAL RECOMMENDED | $9,163 | $6,891 |
$6,410
128,663
kWh
|
$2,798
-
MMBtu
|
$(-45.0) | ||
TOTAL IMPLEMENTED | $3,780 | $850 |
$3,825
76,788
kWh
|
- | $(-45.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs