| Assessment Year | 1992 |
|---|---|
| Principal Product | CONTROL DAMPERS |
| NAICS |
n/a
|
| SIC | 3444: Sheet Metal Work |
| Sales Range | $10 M to 50M |
| # of Employees | 108 |
| Plant Area |
n/a
|
| Annual Production | 23,100
pieces
|
| Production Hrs. Annual | 2,125
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $63,895 | 1,088,804 |
kWh
|
$0.059 |
| Natural Gas | $18,762 | 4,805 |
MMBtu
|
$3.90 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $5,517 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,216 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7441: Replace broken windows and/or window sash | $2,059 | $2,670 | - |
$2,059
-
MMBtu
|
- | |
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,376 | $1,450 |
$1,376
23,447
kWh
|
- | - | |
| 03 | 2.2437: Recover waste heat from equipment | $527 | - | - |
$527
-
MMBtu
|
- | |
| 04 | 2.4239: Eliminate or reduce compressed air usage | $313 | $1,000 |
$313
5,275
kWh
|
- | - | |
| 05 | 3.7214: Reduce or eliminate waste | $999 | - |
$189
3,224
kWh
|
- | $810 | |
| 06 | 2.7314: Reduce ventilation air | $243 | $650 |
$52
879
kWh
|
$191
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $5,517 | $5,770 |
$1,930
32,825
kWh
|
$2,777
-
MMBtu
|
$810 | ||
| TOTAL IMPLEMENTED | $2,216 | $2,450 |
$1,689
28,722
kWh
|
$527
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs