Assessment Year | 1992 |
---|---|
Principal Product | HAMBURGER BUNS |
NAICS |
n/a
|
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
n/a
|
Annual Production | 16,000,000
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $246,489 | 4,580,598 |
kWh
|
$0.054 |
Natural Gas | $86,620 | 20,243 |
MMBtu
|
$4.28 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $38,848 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $11,263 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2621: Modify refrigeration system to operate at a lower pressure | $24,869 | $10,000 |
$24,869
462,192
kWh
|
- | - | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $6,102 | $2,000 |
$6,102
113,423
kWh
|
- | - | |
03 | 2.3212: Optimize plant power factor | $4,116 | $2,408 |
$4,116
-
kWh
|
- | - | |
04 | 2.6232: Install set-back timers | $568 | $400 |
$568
10,551
kWh
|
- | - | |
05 | 2.4133: Use most efficient type of electric motors | $484 | $771 |
$484
4,982
kWh
|
- | - | |
06 | 2.1232: Keep boiler tubes clean | $561 | $135 | - |
$561
-
MMBtu
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $177 | - |
$227
4,103
kWh
|
- | $(-50.0) | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $599 | $150 |
$599
11,137
kWh
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,372 | $3,990 |
$1,372
25,498
kWh
|
- | - | |
TOTAL RECOMMENDED | $38,848 | $19,854 |
$38,337
631,886
kWh
|
$561
-
MMBtu
|
$(-50.0) | ||
TOTAL IMPLEMENTED | $11,263 | $5,314 |
$10,702
118,405
kWh
|
$561
-
MMBtu
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs