| Assessment Year | 1991 |
|---|---|
| Principal Product | BEEF AND BEEF PRODUCTS |
| NAICS |
n/a
|
| SIC | 2011: Meat Packing Plants |
| Sales Range | $10 M to 50M |
| # of Employees | 100 |
| Plant Area |
n/a
|
| Annual Production | 15,000,000
lb
|
| Production Hrs. Annual | 4,800
hrs
|
| Location (State) | Missouri |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $399,264 | 9,027,257 |
kWh
|
$0.044 |
| Natural Gas | $54,975 | 18,109 |
MMBtu
|
$3.04 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $84,731 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.2623: Minimize condenser cooling water temperature | $35,057 | $12,000 |
$35,057
792,790
kWh
|
- | |
| 02 | 2.2623: Minimize condenser cooling water temperature | $14,710 | $12,800 |
$14,710
332,649
kWh
|
- | |
| 03 | 2.4322: Use or replace with energy efficient substitutes | $15,900 | $38,600 |
$15,900
382,181
kWh
|
- | |
| 04 | 2.2437: Recover waste heat from equipment | $18,286 | $39,000 | - |
$18,286
-
MMBtu
|
|
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $622 | - |
$622
14,068
kWh
|
- | |
| 06 | 2.4221: Install compressor air intakes in coolest locations | $156 | $280 |
$156
3,517
kWh
|
- | |
| TOTAL RECOMMENDED | $84,731 | $102,680 |
$66,445
1,525,205
kWh
|
$18,286
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs