Assessment Year | 1991 |
---|---|
Principal Product | COMMERCIAL REFRIGERATORS |
NAICS |
n/a
|
SIC | 3585: Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment |
Sales Range | $10 M to 50M |
# of Employees | 160 |
Plant Area |
n/a
|
Annual Production | 9,000
pieces
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $98,122 | 1,816,823 |
kWh
|
$0.054 |
Natural Gas | $42,697 | 9,441 |
MMBtu
|
$4.52 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $29,000 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7261: Install timers and/or thermostats | $8,570 | - | - |
$8,570
-
MMBtu
|
|
02 | 2.7312: Minimize use of outside make-up air for ventilation except when used for economizer cycle | $7,689 | $200 | - |
$7,689
-
MMBtu
|
|
03 | 2.7314: Reduce ventilation air | $6,174 | $100 |
$2,359
43,669
kWh
|
$3,815
-
MMBtu
|
|
04 | 2.7314: Reduce ventilation air | $1,042 | $350 |
$491
9,086
kWh
|
$551
-
MMBtu
|
|
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $5,351 | $900 |
$5,351
99,062
kWh
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $174 | - |
$174
3,224
kWh
|
- | |
TOTAL RECOMMENDED | $29,000 | $1,550 |
$8,375
155,041
kWh
|
$20,625
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs