Assessment Year | 1990 |
---|---|
Principal Product | CORN CHIPS |
NAICS |
n/a
|
SIC | 2096: Potato Chips, Corn Chips, and Similar Snacks |
Sales Range | $10 M to 50M |
# of Employees | 77 |
Plant Area |
n/a
|
Annual Production | 18,000,000
lb
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $77,113 | 1,579,132 |
kWh
|
$0.049 |
Natural Gas | $155,513 | 62,792 |
MMBtu
|
$2.48 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $7,915 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $7,397 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 3.4115: Recover and reuse cooling water | $4,123 | $7,000 | - | - | $4,123 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $862 | $100 |
$862
17,585
kWh
|
- | - | |
03 | 2.6232: Install set-back timers | $1,130 | $640 |
$1,130
23,154
kWh
|
- | - | |
04 | 2.3212: Optimize plant power factor | $518 | $900 |
$518
-
kWh
|
- | - | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,282 | $100 | - |
$1,282
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $7,915 | $8,740 |
$2,510
40,739
kWh
|
$1,282
-
MMBtu
|
$4,123 | ||
TOTAL IMPLEMENTED | $7,397 | $7,840 |
$1,992
40,739
kWh
|
$1,282
-
MMBtu
|
$4,123 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs