Assessment Year 1988
Principal Product LAUNDRY STARCH
NAICS
n/a
SIC 2842: Specialty Cleaning, Polishing, and Sanitation Preparations
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area
n/a
Annual Production 2,500,000
pieces
Production Hrs. Annual 2,125
hrs
Location (State) Missouri

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $73,779 706,331
kWh
Natural Gas $74,955 18,497
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $16,588 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $12,530

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $7,528 $8,010 $7,528
72,098
kWh
- -
02 2.2444: Use hot process fluids to preheat incoming process fluids $3,098 $500 - $3,098
-
MMBtu
-
03 2.2414: Use waste heat from hot flue gases to preheat $2,831 $4,000 - $2,831
-
MMBtu
-
04 2.1131: Repair faulty insulation in furnaces, boilers, etc $563 $936 - $563
-
MMBtu
-
05 2.2449: Recover heat from exhausted steam, hot air or hot water $664 $800 - $178
-
MMBtu
$486
06 2.4111: Utilize energy-efficient belts and other improved mechanisms $153 - $153
1,465
kWh
- -
07 2.4312: Improve lubrication practices $153 - $153
1,465
kWh
- -
08 2.7441: Replace broken windows and/or window sash $1,598 $28 $31
293
kWh
$1,567
-
MMBtu
-
TOTAL RECOMMENDED $16,588 $14,274 $7,865
75,321
kWh
$8,237
-
MMBtu
$486
TOTAL IMPLEMENTED $12,530 $8,538 $7,865
75,321
kWh
$4,665
-
MMBtu
-
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs