Assessment Year | 1986 |
---|---|
Principal Product | HEAVY DUTY TUCK TRANSMISSIONS |
NAICS |
n/a
|
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 473 |
Plant Area |
n/a
|
Annual Production | 42,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Iowa |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $903,114 | 18,716,003 |
kWh
|
$0.048 |
Natural Gas | $353,943 | 76,412 |
MMBtu
|
$4.63 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $102,813 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $32,007 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $35,188 | $27,000 | - |
$35,188
-
MMBtu
|
- | |
02 | 2.3212: Optimize plant power factor | $18,000 | $30,000 |
$18,000
-
kWh
|
- | - | |
03 | 2.7226: Use computer programs to optimize hvac performance | $11,057 | $5,000 |
$11,057
229,191
kWh
|
- | - | |
04 | 2.4312: Improve lubrication practices | $9,940 | $10,352 |
$9,940
206,038
kWh
|
- | - | |
05 | 2.3191: Use demand controller or load shedder | $8,125 | $6,000 |
$8,125
-
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,890 | $5,585 |
$7,890
163,540
kWh
|
- | - | |
07 | 2.2532: Use only amount of air necessary to prevent explosion hazard | $3,369 | $4,000 | - |
$569
-
MMBtu
|
$2,800 | |
08 | 2.4221: Install compressor air intakes in coolest locations | $2,559 | $525 |
$2,559
53,048
kWh
|
- | - | |
09 | 2.4221: Install compressor air intakes in coolest locations | $2,489 | $315 |
$2,489
51,583
kWh
|
- | - | |
10 | 2.2414: Use waste heat from hot flue gases to preheat | $1,750 | $3,236 | - |
$1,750
-
MMBtu
|
- | |
11 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,456 | - |
$1,456
30,188
kWh
|
- | - | |
12 | 2.6121: Reduce hot water temperature to the minimum required | $990 | - |
$990
20,516
kWh
|
- | - | |
TOTAL RECOMMENDED | $102,813 | $92,013 |
$62,506
754,104
kWh
|
$37,507
-
MMBtu
|
$2,800 | ||
TOTAL IMPLEMENTED | $32,007 | $16,900 |
$32,007
495,018
kWh
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs